TH-GC0424PM2-Z300W Txheej 2 Tswj Ethernet Hloov 4xGigabit Combo (RJ45 / SFP) 24 × 10 / 100 / 1000Base-T PoE

Qauv nab npawb:TH-GC0424PM2-Z300W

Hom Tshuaj:Todahika

  • Hloov cov ntaub ntawv rau lub koob yees duab saib xyuas lub network
  • Tau tshaj IEEE802.3at (30W) thiab IEEE802.3af (15.4w)

Product Detail

Nta

Ordering Information

Specifications

Dimension

Khoom cim npe

Product Description

Gigabit Txheej 2 Tswj PoE Hloov yog Green Energy-Saving PoE Hloov ntawm nws tus kheej.Nrog kev ua haujlwm siab thiab siab ceev Network IC thiab qhov ruaj khov tshaj plaws PoE Chip, PoE cov chaw nres nkoj ntsib IEEE802.3af 15.4w thiab IEEE802.3at 30w.Cov qauv no tuaj yeem muab kev sib txuas tsis sib haum rau 10/ 100/ 1000M Ethernet, thiab PoE fais fab chaw nres nkoj tuaj yeem ntes thiab siv cov khoom siv fais fab uas ua raws li IEEE802.3af / ntawm cov qauv.Cov khoom siv uas tsis yog PoE raug quab yuam thiab tsuas yog xa cov ntaub ntawv xwb.

TH-8G0024M2P

  • Yav dhau los:
  • Tom ntej:

  • ● Hloov cov ntaub ntawv rau lub koob yees duab saib xyuas lub network

    ● 24 x 10/100/1000Mbps auto-sensing PoE Ports, 4 x 10/100/1000Mbps Combo Ports, 1 x Console Ports

    ● Txhawb IEEE802.3/IEEE802.3i/IEEE802.3uIEEE802.3ab/IEEE802.3z, IEEE802.3af/at, store-and-forward

    ● Tau tshaj IEEE802.3at (30W) thiab IEEE802.3af (15.4w)

    ● Ethernet chaw nres nkoj txhawb 10/100/1000M yoog raws thiab PoE ua haujlwm

    ● Vaj Huam Sib Luag qhov taw qhia saib xyuas cov xwm txheej thiab pab kev soj ntsuam tsis ua haujlwm

    ● Txhawb 802.1x chaw nres nkoj authentication, txhawb AAA authentication, txhawb TACACS + authentication;

    ● DOS nres tiv thaiv chaw, ACL nqis

    ● Txhawb WEB, TELNET, CLI, SSH, SNMP, RMON tswj

    ● Txhawb PoE Power Management thiab PoE Watchdog

    ● Kev Tiv Thaiv Kev Tiv Thaiv Hluav Taws Xob: General Hom 4KV, Hom Sib Txawv 2KV

    P/N Kev piav qhia
    TH-GC0424PM2-Z300W
    Txheej 2 Tswj Ethernet Hloov 4xGigabit Combo (RJ45 / SFP)
    24 × 10/100/1000Base-T PoE Chaw nres nkoj, Sab hauv fais fab mov 52V / 5.76A, 300w
    TH-GC0424PM2-Z400W
    Txheej 2 Tswj Ethernet Hloov 4xGigabit Combo (RJ45 / SFP)
    24 × 10/100/1000Base-T PoE Chaw nres nkoj, Sab hauv fais fab mov 52V / 7.69A, 400w

     

    I/O interface  
    Lub zog nkag Tawm tswv yim AC 110-240V, 50/60Hz
    Tsau Chaw nres nkoj 24 x 10/100/1000Mbps PoE Chaw nres nkoj
    4 x 1000M Combo (RJ45 / SFP) Chaw nres nkoj
    1 x RJ45 Console Chaw nres nkoj
    Kev ua tau zoo  
    Hloov Peev Xwm 56gbps ua
    Tshaj tawm 41,66m wb
    Packet Buffer 4 Mb
    Flash Nco 16 MB
    DDR SDRAM 128 MB
    MAC Chaw Nyob 8K
    Jumbo Ncej 9.6kb ua
    VLANs ib 4096
    Hloov hom Khaws thiab xa mus
    MTBF 100000 teev
    Txuj  
    Network raws tu qauv IEEE 802.3: Ethernet MAC raws tu qauv
    IEEE 802.3i: 10BASE-T Ethernet
    IEEE 802.3u: 100BASE-TX Fast Ethernet
    IEEE 802.3ab: 1000BASE-T Gigabit Ethernet
    IEEE 802.3z: 1000BASE-X Gigabit Ethernet (optical fiber)
    IEEE 802.3az: Zog txuag Ethernet
    IEEE 802.3ad: Tus qauv txheej txheem rau kev ua tiav txuas txuas
    IEEE 802.3x: Flow tswj
    IEEE 802.1ab: LLDP/LLDP-MED (Txuas Txheej Txheej Discovery Protocol)
    IEEE 802.1p: LAN Layer QoS/CoS Protocol Traffic Prioritization (Multicast)
    filtering muaj nuj nqi)
    IEEE 802.1q: VLAN Choj Ua Haujlwm
    IEEE 802.1x: Client/Server Access Control thiab Authentication Protocol
    IEEE 802.1d: STP;IEEE 802.1s: MSTP;IEEE 802.1w: RSTP
    PoE raws tu qauv IEEE 802.3af (15.4W);IEEE 802.3 ntawm 30W
    Kev lag luam Standard EMI: FCC Tshooj 15 CISPR (EN55032) chav kawm A
    EMS: EN61000-4-2 (ESD), EN61000-4-4 (EFT), EN61000-4-5 (Surge)
    Kev poob siab: IEC 60068-2-27
    Lub caij nplooj zeeg dawb: IEC 60068-2-32
    Kev vibration: IEC 60068-2-6
    Network Medium 10Base-T: Cat3, 4, 5 lossis siab dua UTP (≤100m)
    100Base-TX: Cat5 lossis siab dua UTP(≤100m)
    1000Base-TX: Cat5 lossis siab dua UTP(≤100m) Optical
    Multimode fiber ntau: 1310nm, 2Km
    Tib hom fiber ntau: 1310nm, 20/40 Km;1550nm, 60/80/100/120Km
    Kev tiv thaiv  
    Daim ntawv pov thawj kev ruaj ntseg CE / FCC / RoHS daim ntawv pov thawj
    Ib puag ncig  
    Ua haujlwm ib puag ncig Ua haujlwm kub: -20 ~ 55 ° C
    Cia kub: -40 ~ 85 ° C
    Ua hauj lwm av noo: 10% ~ 90%, non-condensing
    Cia kub: 5% ~ 90%, non-condensing
    Ua haujlwm siab: siab tshaj 10,000 ko taw
    Cia qhov siab: siab tshaj 10,000 ko taw
    Qhov taw qhia  
    Qhov taw qhia LED PWR (Power Supply)
    SYS (System)
    1-24 PoE & ACT (PoE)
    1-24 Txuas & ACT (Txuas & Txoj Cai)
    25-28 Link (Txuas)
    25-28 Txoj Cai (Act)
    DIP Hloov Rov pib dua
    Neeg kho tshuab  
    Qauv Loj Qhov Loj (L * W * H): 440 * 284 * 44mm
    Pob Dimension (L * W * H): 495 * 350 * 103mm
    Nyhav: 3.5 kg
    Qhov hnyav: 4.25 kg
    Cov ntaub ntawv ntim Thawv loj: 592 * 510 * 375mm
    Packing Qty: 5 units
    Ntim Nyhav: 22.5KG
    Txheej 2 Software Function  
    Chaw Tswj Xyuas Qhib / Disable Port
    Ceev, Duplex, MTU teeb
    Flow-tswj
    Chaw nres nkoj ntaub ntawv txheeb xyuas
    Port Mirroring Txhawb nqa ob sab-txoj kev chaw nres nkoj mirroring
    Chaw nres nkoj ceev txwv Txhawb chaw nres nkoj-raws li cov tswv yim / tso zis bandwidth tswj
    Chaw nres nkoj Isolation Txhawb qhov downlink chaw nres nkoj cais, thiab tuaj yeem sib txuas lus nrog qhov chaw nres nkoj uplink
    Cua daj cua dub Txhawb tsis paub unicast, multicast, tsis paub multicast, tshaj tawm hom cua daj cua dub tua
    Kev tiv thaiv cua daj cua dub raws li kev tswj hwm bandwidth thiab kev lim cua daj cua dub
    Txuas Aggregation Txhawb static phau ntawv aggregation
    Txhawb LACP dynamic aggregation
    VLAN Nkag mus
    Lub cev
    Hybrid
    Txhawb chaw nres nkoj, raws tu qauv, MAC-raws li VLAN muab faib
    Txhawb GVRP dynamic VLAN sau npe
    Suab VLAN
    MAC Txhawb static ntxiv, tshem tawm
    MAC chaw nyob txwv kev kawm
    Txhawb dynamic aging lub sij hawm teem
    Tsob ntoo Txhawb STP spanning ntoo raws tu qauv
    Txhawb RSTP Rapid Spanning Tree Protocol
    Txhawb MSTP Rapid Spanning Tree Protocol
    Multicast Txhawb static ntxiv, tshem tawm
    IGMP-snooping
    Txhawb MLD-Snooping
    Txhawb nqa v1/2/3 dynamic multicast saib
    DDM Txhawb SFP / SFP + DDM
    Extended Function  
    ACL Raws li qhov chaw MAC, qhov chaw MAC, hom raws tu qauv, qhov chaw IP, qhov chaw
    IP, L4 chaw nres nkoj
    QoS Raws li 802.1p (COS) kev faib tawm
    Raws li DSCP kev faib tawm
    Kev faib tawm raws li qhov chaw IP, qhov chaw IP, thiab tus lej chaw nres nkoj
    Txhawb SP, WRR lub sijhawm teem sijhawm
    Txhawb nqa tus nqi txwv CAR
    LLDP Txhawb LLDP txuas kev tshawb nrhiav raws tu qauv
    Cov neeg siv kev teeb tsa Ntxiv/rho tawm cov neeg siv
    Log Tus neeg siv nkag mus, kev ua haujlwm, xwm txheej, txheej xwm
    Kev tawm tsam DOS tiv thaiv
    Txhawb CPU tiv thaiv thiab txwv tus nqi xa CPU pob ntawv
    ARP losis tswvyim dabtsi (IP, MAC, PORT binding)
    Daim ntawv pov thawj Txhawb 802.1x chaw nres nkoj authentication
    Txhawb AAA ntawv pov thawj
    Kev kuaj mob network Txhawb ping, telnet, kab
    Qhov System Management Ntaus pib dua, teeb tsa txuag / rov qab, txhim kho kev tswj hwm, sijhawm teem sijhawm, thiab lwm yam.
    Kev tswj hwm muaj nuj nqi  
    CLI Txhawb serial chaw nres nkoj hais kom ua kab tswj
    SSH Txhawb SSHv1/2 tswj chaw taws teeb
    TELNET Txhawb telnet tswj chaw taws teeb
    WEB Txhawb Cov Txheej Txheem 2, Txheej 2 thiab Txheej 3 saib
    SNMP SNMP V1/V2/V3
    Kev them nyiaj yug ntxiab: ColdStart, WarmStart, LinkDown, LinkUp
    RMON Txhawb RMON v1
    PoE Txhawb PoE fais fab mov
    Lwm cov haujlwm Txhawb DHCP Snooping, Option82, DHCP Server
    Txhawb kev tshawb nrhiav dynamic ARP
    Txhawb TACACS + ntawv pov thawj
    Txhawb DNS ntawv pov thawj
    Txhawb kev ruaj ntseg chaw nres nkoj
    Txhawb MVR raws tu qauv
    Txhawb nqa cable nrhiav VCT muaj nuj nqi
    Txhawb UDLD raws tu qauv

     

    Dimension (4)

    Sau koj cov lus ntawm no thiab xa tuaj rau peb